Coverart for item
The Resource Medical applications of titanium and its alloys : the material and biological issues, Stanley A. Brown and Jack E. Lemons, Editors, (electronic book)

Medical applications of titanium and its alloys : the material and biological issues, Stanley A. Brown and Jack E. Lemons, Editors, (electronic book)

Label
Medical applications of titanium and its alloys : the material and biological issues
Title
Medical applications of titanium and its alloys
Title remainder
the material and biological issues
Statement of responsibility
Stanley A. Brown and Jack E. Lemons, Editors
Contributor
Subject
Genre
Language
eng
Member of
Cataloging source
ASTM
LC call number
R857.M3
Nature of contents
patent document
http://library.link/vocab/relatedWorkOrContributorDate
1943-
http://library.link/vocab/relatedWorkOrContributorName
  • Brown, Stanley A.
  • Lemons, Jack E
  • ASTM International.
Series statement
ASTM STP
Series volume
1272
http://library.link/vocab/subjectName
  • Biocompatible Materials
  • Titanium alloys
  • Metals in medicine
  • Biomedical Technology
  • Equipment and Supplies
  • Titanium
Label
Medical applications of titanium and its alloys : the material and biological issues, Stanley A. Brown and Jack E. Lemons, Editors, (electronic book)
Instantiates
Publication
Note
  • "ASTM Stock Number: STP1272."
  • "ASTM Publication Code Number (PCN):04-012720-54"
  • "The symposium was sponsored by ASTM Committee F-4 on Medical and Surgical Materials and Devices, as a joint effort with the Medical Applications Committee of the International Titanium Association (ITA), formerly the Titanium Development Association, and the Bioengineering Committee of the American Academy of Orthopaedic Surgeons (AAOS)."-- Foreword
  • For off-campus access, use Internet Explorer or Firefox in the Web folder of Apps Anywhere - http://apps.liv.ac.uk
Bibliography note
Includes bibliographical references and indexes
Carrier category
online resource
Carrier category code
  • cr
Carrier MARC source
rdacarrier
Content category
text
Content type code
  • txt
Content type MARC source
rdacontent
Contents
Overview / S. A. Brown and J. E. Lemons -- Processing and ti-6a1-4v -- Titanium alloys as implant materials / M. A. Imam and A. C. Fraker -- Manufacturing Processes for Semi-Finished Titanium Biomedical Alloys / R. M. Davis and R. M. Forbes Jones -- Taguchi experiment on the mechanical properties of sintered titanium 6-4 / R. R. Peterson and C. V. French -- New alloys -- New titanium alloys to be considered for medical implants / Y. Okazaki, Y. Ito, A. Ito and T. Tateishi -- Characterization of ti-15mo beta titanium alloy for orthopaedic implant applications / L. D. Zardiackas, D. W. Mitchell and J. A. Disegi -- Microstructure and properties of a new beta titanium alloy, ti-12mo-6zr-2fe, developed for surgical implants / K. K. Wang, L. J. Gustavson and J. H. Dumbleton -- Optimization of properties of ti-15mo-2.8nb-3a1-0.2si and ti-15mo-2.8nb-0.2si-0.260 beta titanium alloys for application in prosthetic implants / S. K. Bhambri, R. H. Shetty and L. N. Gilbertson -- Mechanical and tribological properties and biocompatibility of diffusion hardened ti-13nb-13zr-a new titanium alloy for surgical implants / A. K. Mishra, J. A. Davldson, R. A. Poggie, P. Kovacs, and T. J. Fitzgerald -- Porous coatings -- Methods of detecting and predicting microfractures in titanium / D. H. Kohn, C. C. Ko, S. J. Hollister, D. Snoeyink, J. Awerbuch, and P. Ducheyne -- Evaluation of the corrosion fatigue behavior of porous coated ti-6ai-4v / H. Hampel and H. R. Piehler -- A novel porous coating geometry to improve the fatigue strength of ti-6ai-4v implant alloy / D. Wolfarth and P. Ducheyne -- Corrosion, laboratory studies -- Chemical and electrochemical aspects of the biocompatibility of titanium and its alioys / P. Kovacs and J. A. Davidson -- Passive dissolution of titanium in biological environments-- K. E. Healy and P. Ducheyne -- Corrosion behavior of dental casting alloys coupled with titanium / A. A. Chohayeb, A. C. Fraker, F. C. Eichmiller, R. M. Waterstrat, and J. Boyd -- Titanium oxide film fracture and repassivation: the effect of potential, pH, and Aeration / J. L. Gilbert, C. A. Buckley, and E. P. Lautenschlager -- Fretting and wear testing -- Transitional behavior in ti-6ai-4v fretting corrosion / B. J. Smith and P. Ducheyne -- Effects of material combination, surface treatment, and environment of fretting corrosion of ti-6ai-4v / S. A. Brown, J. S. Kawalec, A. C. Montague, K. Merritf, and J. H. Payer -- Mechanical and corrosion properties of nitrogen diffusion hardened ti-6ai-4v Alloy / R. H. Shetty -- Characterizing the fretting fatigue behavior of ti-6ai-4v in modular joints / D. W. Hoeppner and V. Chandrasekaran -- Wear of Titanium 6-4 Alloy in Laboratory Tests and in Retrieved Human Joint Replaeements / H. A. Mckellop, T. Rostlund, E. Ebramzadeh, and A. Sarmiento -- Biological issues -- The in vitro response to particulate titanium alloy / S. D. Rogers, D. W. Howie, D. R. Haynes, and M. J. Pearcy -- Response of titanium surfaces to simulated biological environments / J. L. Ong, L. C. Lucas, and C. W. Prince -- In vitro osteoblast responses to cpti and ti-6ai-4v alloy / J. C. Keller, C. M. Stanford, R. A. Draughn, and J. P. Wightman -- Induction of bone resorbing agents by titanium particulates: responses of macrophages, fibroblasts and osteoblasts in vitro / T. T. Glant, J. Yau, and J. J. Jacobs -- Determination of in vivo titanium release from a non-articulating commercially pure titanium implant / P. D, Bianco, P. Ducheyne, and J. M. Cuckler -- Distribution of titanium and vanadium salts and corrosion products in cells, fluids, and organs in vivo and in cell culture in vitro / K. Merritt and S. A. Brown -- Clinical experience -- Clinical studies on titanium and stainless steel plates (LC-DCP). A comparative evaluatiou / A. Ungersbock, O. E. M. Pohler, F. W. Baumgart, B. Rahn, and S. M. Perren -- Wear and osteolysis in relation to prostheses design and materials / D. W. Howe and A. Mcgee -- A 3-year prospective study of serum titanium levels in patients with primary total hip replacements / J. J. Jacobs, A. K. Skipor, J. Black, L. M. Patverson, W. P. Paprosky, and J. O. Galante -- Retrieval analysis of ti-6ai-4v miller-galante total knee replacements / M. J. Kraay, V. M. Goldberg, S. A. Brown, and K. Merritt
Control code
SCOPE0578
Dimensions
unknown
Extent
[6], ix-xii, [1], 3-421 p.
Form of item
electronic
Isbn
9780803120105
Media category
computer
Media MARC source
rdamedia
Media type code
  • c
Other physical details
ill., charts, diagrs., tables.
Reformatting quality
not applicable
Reproduction note
Electronic resource.
Specific material designation
remote
Label
Medical applications of titanium and its alloys : the material and biological issues, Stanley A. Brown and Jack E. Lemons, Editors, (electronic book)
Publication
Note
  • "ASTM Stock Number: STP1272."
  • "ASTM Publication Code Number (PCN):04-012720-54"
  • "The symposium was sponsored by ASTM Committee F-4 on Medical and Surgical Materials and Devices, as a joint effort with the Medical Applications Committee of the International Titanium Association (ITA), formerly the Titanium Development Association, and the Bioengineering Committee of the American Academy of Orthopaedic Surgeons (AAOS)."-- Foreword
  • For off-campus access, use Internet Explorer or Firefox in the Web folder of Apps Anywhere - http://apps.liv.ac.uk
Bibliography note
Includes bibliographical references and indexes
Carrier category
online resource
Carrier category code
  • cr
Carrier MARC source
rdacarrier
Content category
text
Content type code
  • txt
Content type MARC source
rdacontent
Contents
Overview / S. A. Brown and J. E. Lemons -- Processing and ti-6a1-4v -- Titanium alloys as implant materials / M. A. Imam and A. C. Fraker -- Manufacturing Processes for Semi-Finished Titanium Biomedical Alloys / R. M. Davis and R. M. Forbes Jones -- Taguchi experiment on the mechanical properties of sintered titanium 6-4 / R. R. Peterson and C. V. French -- New alloys -- New titanium alloys to be considered for medical implants / Y. Okazaki, Y. Ito, A. Ito and T. Tateishi -- Characterization of ti-15mo beta titanium alloy for orthopaedic implant applications / L. D. Zardiackas, D. W. Mitchell and J. A. Disegi -- Microstructure and properties of a new beta titanium alloy, ti-12mo-6zr-2fe, developed for surgical implants / K. K. Wang, L. J. Gustavson and J. H. Dumbleton -- Optimization of properties of ti-15mo-2.8nb-3a1-0.2si and ti-15mo-2.8nb-0.2si-0.260 beta titanium alloys for application in prosthetic implants / S. K. Bhambri, R. H. Shetty and L. N. Gilbertson -- Mechanical and tribological properties and biocompatibility of diffusion hardened ti-13nb-13zr-a new titanium alloy for surgical implants / A. K. Mishra, J. A. Davldson, R. A. Poggie, P. Kovacs, and T. J. Fitzgerald -- Porous coatings -- Methods of detecting and predicting microfractures in titanium / D. H. Kohn, C. C. Ko, S. J. Hollister, D. Snoeyink, J. Awerbuch, and P. Ducheyne -- Evaluation of the corrosion fatigue behavior of porous coated ti-6ai-4v / H. Hampel and H. R. Piehler -- A novel porous coating geometry to improve the fatigue strength of ti-6ai-4v implant alloy / D. Wolfarth and P. Ducheyne -- Corrosion, laboratory studies -- Chemical and electrochemical aspects of the biocompatibility of titanium and its alioys / P. Kovacs and J. A. Davidson -- Passive dissolution of titanium in biological environments-- K. E. Healy and P. Ducheyne -- Corrosion behavior of dental casting alloys coupled with titanium / A. A. Chohayeb, A. C. Fraker, F. C. Eichmiller, R. M. Waterstrat, and J. Boyd -- Titanium oxide film fracture and repassivation: the effect of potential, pH, and Aeration / J. L. Gilbert, C. A. Buckley, and E. P. Lautenschlager -- Fretting and wear testing -- Transitional behavior in ti-6ai-4v fretting corrosion / B. J. Smith and P. Ducheyne -- Effects of material combination, surface treatment, and environment of fretting corrosion of ti-6ai-4v / S. A. Brown, J. S. Kawalec, A. C. Montague, K. Merritf, and J. H. Payer -- Mechanical and corrosion properties of nitrogen diffusion hardened ti-6ai-4v Alloy / R. H. Shetty -- Characterizing the fretting fatigue behavior of ti-6ai-4v in modular joints / D. W. Hoeppner and V. Chandrasekaran -- Wear of Titanium 6-4 Alloy in Laboratory Tests and in Retrieved Human Joint Replaeements / H. A. Mckellop, T. Rostlund, E. Ebramzadeh, and A. Sarmiento -- Biological issues -- The in vitro response to particulate titanium alloy / S. D. Rogers, D. W. Howie, D. R. Haynes, and M. J. Pearcy -- Response of titanium surfaces to simulated biological environments / J. L. Ong, L. C. Lucas, and C. W. Prince -- In vitro osteoblast responses to cpti and ti-6ai-4v alloy / J. C. Keller, C. M. Stanford, R. A. Draughn, and J. P. Wightman -- Induction of bone resorbing agents by titanium particulates: responses of macrophages, fibroblasts and osteoblasts in vitro / T. T. Glant, J. Yau, and J. J. Jacobs -- Determination of in vivo titanium release from a non-articulating commercially pure titanium implant / P. D, Bianco, P. Ducheyne, and J. M. Cuckler -- Distribution of titanium and vanadium salts and corrosion products in cells, fluids, and organs in vivo and in cell culture in vitro / K. Merritt and S. A. Brown -- Clinical experience -- Clinical studies on titanium and stainless steel plates (LC-DCP). A comparative evaluatiou / A. Ungersbock, O. E. M. Pohler, F. W. Baumgart, B. Rahn, and S. M. Perren -- Wear and osteolysis in relation to prostheses design and materials / D. W. Howe and A. Mcgee -- A 3-year prospective study of serum titanium levels in patients with primary total hip replacements / J. J. Jacobs, A. K. Skipor, J. Black, L. M. Patverson, W. P. Paprosky, and J. O. Galante -- Retrieval analysis of ti-6ai-4v miller-galante total knee replacements / M. J. Kraay, V. M. Goldberg, S. A. Brown, and K. Merritt
Control code
SCOPE0578
Dimensions
unknown
Extent
[6], ix-xii, [1], 3-421 p.
Form of item
electronic
Isbn
9780803120105
Media category
computer
Media MARC source
rdamedia
Media type code
  • c
Other physical details
ill., charts, diagrs., tables.
Reformatting quality
not applicable
Reproduction note
Electronic resource.
Specific material designation
remote

Library Locations

Processing Feedback ...